inventory

Strong marketing of inventory, fully integrated

KGVP650 GENSET

RATING GUIDELINES
PRIME POWER rating corresponds to ISO Standard Power for continuous operation. It is applicable for supplying electrical power at variable load for an unlimited number of hours instead of commercially purchased power. A10 % overload capability for govering purpose is available for this rating.
MAXIMUM STANDBY POWER rating corresponds to ISO Standard Fuel Stop Power. It is applicable for supplying standby electrical power at variable load in areas with well established electrical networks in the event of normal utility power failure. No overload capability is available for this rating. 1 hp = 1 kW x 1.36

  • There are no features available

Engine Make & Model
Origin
Alternator Type
Control Panel
Circuit Breaker Type
Tropical Cooling System
Fully Electronic with Volvo Penta EMS 2
Emission Compliant
CANBUS SAEJ1939 Interface
No. of Cylinders / Alignment
Cycle
Aspiration
Injection
Bore, mm
Stroke, mm
Displacement,I
Compression Ratio
Starting
Alternators, Amps
Prime Power
521KWe / 652KVA
547KWe / 684KVA
Volvo Penta TWD1644GE
SWEDEN
Stamford HCI544F
Deap Sea - 7310
3 Pole MCCB
55°C
6 In Line
4 Stroke
Turbocharged
Electronic
144
165
16.12
16.8:1
24V Electric
24V/80A
Standby Power
573KWe / 717KVA
602KWe / 752KVA
Genset Specifications
Engine Technical Data
No. of Bearings
Insulation System
Excitation
Voltage Regulator
Protection
Temperature Rise,°C
Regulation
No. of Phases
No. of Poles
Single Bearing
Class H
Self Excited
AS440
IP23
125
±1.0%
3
4
Alternator Technical Data
KGVP650 GENSET
Image for illustration purposes only
Height(m)
2.05
Width(m)
1.40
Length(m)
3.85
Weight(kg)
4664
Tank Capacity(L)
515
Dimensions & Weights
International Standards
Engine confirm to ISO 9001: 2000, ISO 14001, ISO10054, ISO 3046,BS 5514,DIN 6271.
Alternator confirm to ISO 9001, ISO 14001, BS EN 60034, BS 5000, VDE 0530, NEMA MG1-32, IEC34 CSA C22.2-100, AS 1359, BS 6861 1, B En 61000-6-2:2001
RATING GUIDELINES
PRIME POWER rating corresponds to ISO Standard Power for continuous operation. It is applicable for supplying electrical power at variable load for an unlimited number of hours instead of commercially purchased power. A10 % overload capability for govering purpose is available for this rating.
MAXIMUM STANDBY POWER rating corresponds to ISO Standard Fuel Stop Power. It is applicable for supplying standby electrical power at variable load in areas with well established electrical networks in the event of normal utility power failure. No overload capability is available for this rating. 1 hp = 1 kW x 1.36
1500rpm, 50 Hz
1800rpm, 60Hz
39.96
70.42
64.4
103
95.619
137.39
Fuel System
50%
75%
100%
*Prime Power (l/hr)

Make: VOLVO Penta
Model: Generator
Back to top